| Prefix | ID# | Name |
| CC | 1 | Control Prefix |
| DD | 2 | Configuration Prefix |
| AA0 | 3 | Control Unlock |
| AA1 | 4 | Repeater Off |
| AA2 | 5 | Repeater On |
| AA3 | 6 | DTMF UP/DN |
| AA4 | 7 | Warm Restart |
| AA5 | 8 | Aux. Repeater Off/On |
| AA6 | 9 | Set BCD Frequency |
| AA7 | 10 | Control Patch Logon |
| AA8 | 11 | Play User Bulletin |
| AA9 | 12 | Autopatch Cancel |
| AB0 | 13 | Tone Test |
| AB1 | 14 | Autopatch |
| AB2 | 15 | Read Temperature F |
| AB3 | 16 | Read Temperature C |
| AB4 | 17 | Read Input |
| AB5 | 18 | Set Local Output |
| AB5 | 18 | Set External Output |
| AB6 | 19 | Emergency Speed Call |
| AB7 | 20 | Speed Call Bank 1 |
| AB72 | 21 | Speed Call Bank 2 |
| AB73 | 22 | Speed Call Bank 3 |
| AB74 | 23 | Speed Call Bank 4 |
| AB8 | 24 | Time Talk |
| AB9 | 25 | Auxiliary Patch Cancel |
| AC0 | 26 | Autopatch Extend |
| AC1 | 27 | CT Test |
| AC2 | 28 | Macro Execute Bank 1 |
| AC3 | 29 | Macro Execute Bank 2 |
| AC4 | 30 | Macro Execute Bank 3 |
| AC5 | 31 | Macro Execute Bank 4 |
| AC6 | 32 | SPI Command |
| AC7 | 33 | Pulse Local Output |
| AC7 | 33 | Pulse External Output |
| AC8 | 34 | SPI #4 Command |
| AC9 | 35 | SPI #5 Command |
| AD0 | 36 | SPI #6 Command |
| AD1 | 37 | SPI #7 Command |
| AD2 | 38 | TR Control port A |
| AD3 | 39 | TR Control port B |
| AD4 | 40 | TR Control port C |
| AD5 | 41 | TR Control port D |
| 999 | 42 | Party Line Autopatch |
| AD6 | 43 | User DTMF Repeat |
| AD7 | 44 | S Meter Peak |
| AD8 | 45 | S Meter Average |
| AD9 | 46 | Configuration Unlock |
| BA0 | 47 | Secondary Patch #1 |
| BA1 | 48 | Secondary Patch #2 |
| BA2 | 49 | Secondary Patch #3 |
| BA3 | 50 | Date Talk |
| BA4 | 51 | Set CTCSS Frequency |
| BA5 | 52 | Set CTCSS Mode |
| BA6 | 53 | Auxiliary Re-dial |
| BA7 | 54 | Macro Execute Bank 5 |
| BA8 | 55 | Macro Execute Bank 6 |
| BA9 | 56 | Macro Execute Bank 7 |
| BB0 | 57 | Macro Execute Bank 8 |
| BB1 | 58 | Reverse Autopatch |
| BB2 | 59 | Set RBI-1 Power |
| BB3 | 60 | Page Two Tone |
| BB4 | 61 | Macro Exec. #81 |
| BB5 | 62 | Macro Exec. #82 |
| BB6 | 63 | Macro Exec. #83 |
| BB7 | 64 | Macro Exec. #84 |
| BB8 | 65 | Macro Exec. #85 |
| BB9 | 66 | Macro Exec. #86 |
| BC0 | 67 | Macro Exec. #87 |
| BC1 | 68 | Macro Exec. #88 |
| BC2 | 69 | User cntl. Patch Logon |
| Prefix | Name |
| 1 | Speech Supress Toggle |
| 400 | Speed Call Program |
| 401 | Sysop Reverse Patch |
| 403 | Speed Call Erase |
| 405 | Control Patch Logoff |
| 406 | Control Patch Monitor |
| 407 | Secondary Patch Enable |
| 408 | Don't Answer Next |
| 409 | Read Last Number |
| 410 | Set Clock |
| 420 | TX Lock |
| 439 | Lock Security |
| 442 | DTMF Access Control |
| 450 | Tail Message Enable |
| 452 | ID Bulliten Enable |
| 453 | ID Interrupt Mode |
| 455 | Machine Alert |
| 459 | ID Force |
| 460 | External Pot Set |
| 471 | Set Scheduler Event Time |
| 473 | Event Enable |
| 474 | Set Scheduler Event Macro |
| 475 | Command Trigger Assign |
| 476 | LTiZ Trigger Assign |
| 477 | LTiZ Detect Time |
| 479800 | Event Re-Synchronize |
| 480 | Recall State |
| 490 | Display Control |
| Prefix | Name |
| 480 | Store State |
| 485 | SIMTEK store/recall |
| 500 | Audio Level Set |
| 501 | TX Audio Level Set |
| 505 | Set BCD Mode |
| 510 | Timer Set |
| 512 | Set Output Pulse Timing |
| 515 | Disable Clock |
| 517 | Clock Smoothing |
| 520 | Prefix Assign |
| 522 | Aux. Delimiter mode |
| 525 | User Function Enable |
| 530 | Control Patch Enable |
| 531 | Patch Courtesy Tone |
| 532 | Number of Rings |
| 533 | Remote Patch Enable |
| 535 | Modem Up/Down |
| 534 | Reverse Patch Mode |
| 536 | Modem On Line |
| 538 | Set Baud Rate |
| 539 | DTMF Log Echo |
| 540 | Remote Base Action |
| 541 | TR Priority Set |
| 542 | TR Mode |
| 546 | CTCSS Mode Set |
| 550 | CT Allocate |
| 551 | CT Edit Mode |
| 552 | DTMF Cover Tone |
| 553 | Voter CT Assign |
| 554 | Voter Remote Base Mode |
| 555 | Message Assign |
| 556 | Message Play |
| 560 | CW Speed |
| 565 | CW Frequency |
| 570 | Voter Port Assign |
| 572 | Voter CT Mode |
| 574 | Voter CW String Enable |
| 575 | Voter Active Level |
| 580 | Text Edit |
| 590 | Macro Enter |
| 591 | Macro Enter Abort |
| 592 | Macro Enter Save |
| 596 | Abort Macro if True |
| 597 | Abort Macro if False |
| 598 | Macro User Flags |
| 599 | Paramter Designate |
| 600 | High Resolution Mode |
| 605 | S Meter Calibrate |
| 610 | Set Output Active Level |
| 630 | Dial Prefix Enter |
| 632 | Dial Prefix Enable |
| 633 | Patch Hang-up Set |
| 634 | Valid Patch Length |
| 635 | Patch Hang-up Read |
| 636 | Patch Options Enable |
| 637 | Reverse Patch Wait |
| 638 | Ring Match Program |
| 639 | Patch Busy Override |
| 650 | Scale and Offset |
| 652 | Assign Units |
| 670 | Scheduler Control |
| 800 | Read Firmware Version |
| Name | Prefix |
| Abort Macro if False | 597 |
| Abort Macro if True | 596 |
| Assign Units | 652 |
| Audio Level Set | 500 |
| Autopatch | AB1 |
| Autopatch Cancel | AA9 |
| Autopatch Extend | AC0 |
| Aux. Delimiter mode | 522 |
| Aux. Repeater Off/On | AA5 |
| Auxiliary Patch Cancel | AB9 |
| Auxiliary Re-dial | BA6 |
| Clock Smoothing | 517 |
| Command Trigger Assign | 475 |
| Configuration Prefix | DD |
| Configuration Unlock | AD9 |
| Control Patch Enable | 530 |
| Control Patch Logoff | 405 |
| Control Patch Logon | AA7 |
| Control Patch Monitor | 406 |
| Control Prefix | CC |
| Control Unlock | AA0 |
| CT Allocate | 550 |
| CT Edit Mode | 551 |
| CT Test | AC1 |
| CTCSS Mode Set | 546 |
| CW Frequency | 565 |
| CW Speed | 560 |
| Date Talk | BA3 |
| Dial Prefix Enable | 632 |
| Dial Prefix Enter | 630 |
| Disable Clock | 515 |
| Display Control | 490 |
| Don't Answer Next | 408 |
| DTMF Access Control | 442 |
| DTMF Cover Tone | 552 |
| DTMF Log Echo | 539 |
| DTMF UP/DN | AA3 |
| Emergency Speed Call | AB6 |
| Event Enable | 473 |
| Event Re-Synchronize | 479800 |
| External Pot Set | 460 |
| High Resolution Mode | 600 |
| ID Bulletin Enable | 452 |
| ID Force | 459 |
| ID Interrupt Mode | 453 |
| Lock Security | 439 |
| LTiZ Trigger Assign | 476 |
| LTiZ Detect Time | 477 |
| Machine Alert | 455 |
| Macro Enter | 590 |
| Macro Enter Abort | 591 |
| Macro Enter Save | 592 |
| Macro Execute Bank 1 | AC2 |
| Macro Execute Bank 2 | AC3 |
| Macro Execute Bank 3 | AC4 |
| Macro Execute Bank 4 | AC5 |
| Macro Execute Bank 5 | BA7 |
| Macro Execute Bank 6 | BA8 |
| Macro Execute Bank 7 | BA9 |
| Macro Execute Bank 8 | BB0 |
| Macro Exec. #81 | BB4 |
| Macro Exec. #82 | BB5 |
| Macro Exec. #83 | BB6 |
| Macro Exec. #84 | BB7 |
| Macro Exec. #85 | BB8 |
| Macro Exec. #86 | BB9 |
| Macro Exec. #87 | BC0 |
| Macro Exec. #88 | BC1 |
| Macro User Flags | 598 |
| Message Assign | 555 |
| Message Play | 556 |
| Modem On Line | 536 |
| Modem Up/Down | 535 |
| Number of Rings | 532 |
| Page Two Tone | BB3 |
| Parameter Designate | 599 |
| Party Line Autopatch | 999 |
| Patch Busy Override | 639 |
| Patch Courtesy Tone | 531 |
| Patch Hang-up Read | 635 |
| Patch Hang-up Set | 633 |
| Patch Options Enable | 636 |
| Play User Bulletin | AA8 |
| Prefix Assign | 520 |
| Pulse Local/External Output | AC7 |
| Read Firmware Version | 800 |
| Read Input | AB4 |
| Read Last Number | 409 |
| Read Temperature C | AB3 |
| Read Temperature F | AB2 |
| Recall State | 480 |
| Remote Base Action | 540 |
| Remote Patch Enable | 533 |
| Repeater Off | AA1 |
| Repeater On | AA2 |
| Reverse Autopatch | BB1 |
| Reverse Patch Mode | 534 |
| Reverse Patch Wait | 637 |
| Ring Match Program | 638 |
| S Meter Average | AB8 |
| S Meter Calibrate | 605 |
| S Meter Peak | AB7 |
| Scale and Offset | 650 |
| Scheduler Control | 670 |
| Secondary Patch #1 | BA0 |
| Secondary Patch #2 | BA1 |
| Secondary Patch #3 | BA2 |
| Secondary Patch Enable | 407 |
| Set Baud Rate | 538 |
| Set BCD Frequency | AA6 |
| Set BCD Mode | 505 |
| Set Clock | 410 |
| Set CTCSS Frequency | BA4 |
| Set CTCSS Mode | BA5 |
| Set Local/External Output | AB5 |
| Set Output Active Level | 610 |
| Set Pulse Timing | 512 |
| Set RBI-1 Power | BB2 |
| Set Scheduler Event Macro | 474 |
| Set Scheduler Event Time | 471 |
| SIMTEK store/recall | 485 |
| Speech Supress Toggle | 1 |
| Speed Call Bank 1 | AB7 |
| Speed Call Bank 2 | AB72 |
| Speed Call Bank 3 | AB73 |
| Speed Call Bank 4 | AB74 |
| Speed Call Erase | 403 |
| Speed Call Program | 400 |
| SPI #4 Command | AC8 |
| SPI #5 Command | AC9 |
| SPI #6 Command | AD0 |
| SPI #7 Command | AD1 |
| SPI Command | AC6 |
| Store State | 480 |
| Sysop Reverse Patch | 401 |
| Tail Message Enable | 450 |
| Text Edit | 580 |
| Time Talk | AB8 |
| Timer Set | 510 |
| Tone Test | AB0 |
| TR Control port A | AD2 |
| TR Control port B | AD3 |
| TR Control port C | AD4 |
| TR Control port D | AD5 |
| TR Mode | 542 |
| TR Priority Set | 541 |
| TX Audio Level Set | 501 |
| TX Lock | 420 |
| User cntl. Patch Logon | BC2 |
| User DTMF Repeat | AD6 |
| User Function Enable | 525 |
| Valid Patch Length | 634 |
| Voter Active Level | 575 |
| Voter CT Assign | 553 |
| Voter CT Mode | 572 |
| Voter CW String Enable | 574 |
| Voter Port Assign | 570 |
| Voter Remote Base Mode | 554 |
| Warm Restart | AA4 |
| Command Description | Keyword |
| Add phone number to Lock-In list | ADDIN |
| Add phone number to Lock-Out list | ADDOUT |
| Clear Speed Dial Slot | SDCLR |
| Command Help | ? |
| Control Autopatch Disconnect | HANG |
| Control RX Simulate | CRX |
| Courtesy Tone Assign | CTSEL |
| Courtesy Tone Enter | CTENT |
| Courtesy Tone Delete | DELETE |
| Delete phone number from Lock-In list | DELIN |
| Delete phone number from Lock-Out list | DELOUT |
| DTMF Cover Tone Status | COVER |
| Force Repeater ID | IDCLR |
| Interrogate Firmware Version | VERSION |
| Interrogate Lock-In List | LOCKIN |
| Interrogate Lock-Out List | LOCKOUT |
| Line Feed Mode | LF |
| List Macro commands | MACRO |
| List Message Assignments | ASSIGN |
| List Speed Dial Slots | SDLIST |
| Memory Restore | LOAD |
| Memory Save | SAVE |
| Modem Connect | DCECON |
| Modem Initialize on Reset | MODEM |
| Modem ON-LINE | DCEUP |
| Modem OFF-LINE | DCEDN |
| Program Speed Dial Slot | SDSET |
| Read Last or Current Tone entries | TONBUF |
| Repeater State Control | STATE |
| Scheduler Control | CONTROL |
| Scheduler Event List | SCHEDULE |
| Security Logon | INGET |
| Serial Port Connect Type | SCIC |
| Serial Port Security Logoff | LOGOFF |
| +++NO | |
| NO | |
| Set Active input levels for COS | LEVC |
| Set Active input levels for Logic Outputs | LEVO |
| Set Active input levels for Voter Logic | LEVV |
| Set Dial-Out Prefix Status | APREF |
| Set Digital Pot | POT |
| Set DTMF Access Status | TTAXS |
| Set Global CW Frequency | CWFR |
| Set Global CW Speed | CWSP |
| Set ID Bulletin Status | BBSET |
| Set Modem Escape Character | ESCAP |
| Set Password | PASSET |
| Set Software Handshake Mode | HANDS |
| Set Tail Message Status | TALSET |
| Set Timer | TIMER |
| Set TX Digital Pot | TPOT |
| Soft System Reset | RESET |
| Text Message Entry | CALL |
| DIALPFX | |
| MESSAGE | |
| SITNAM | |
| Transfer Courtesy Tone to the Edit Buffer | CTGET |
| Transfer Courtesy Tone to Internal Storage | CTSTOR |
| View DTMF Digit log | LLOG |
| Voter Courtesy Tone Assign | VCTSEL |
| Word List Help | WORDS |
(speech pause) 44 cw (,) 44 cw (-) 45 cw (.) 46 cw (/) 47 cw (=) 61 cw (?) 63 cw (pause) 32 A 65 ABORT 23 ABOUT 168 ABOVE 396 ACCELERATED 412 ACKNOW 390 ACTION 360 ADJUST 92 ADVISE 363 AERIAL 384 AFFIRMITIVE 316 AIR 351 ALERT 91 ALL 119 ALOFT 356 ALPHA 201 ALTERNATE 346 ALTITUDE 418 AMPS 37 AND 96 ANSWER 112 APPROACH 392 AREA 298 ARRIVAL 389 AS 395 AT 118 AUTOMATIC 232 B 66 BANK 411 BASE 110 BELOW 352 BETWEEN 258 BLOWING 348 BOOST 425 BRAVO 259 BREAK 101 BROKEN 337 BUTTON 202 BY 318 C 67 CABIN 388 CALIBRATE 309 CALL 25 CALM 397 CANCEL 120 CAUTION 306 CEILING 338 CELSIUS 321 CENTER 380 CHANGE 14 CHARLIE 284 CHECK 97 CIRCUIT 299 CLEAR 347 CLIMB 410 CLOCK 256 CLOSED 377 COMPLETE 6 CONNECT 300 CONTACT 373 CONTROL 117 COURSE 368 CRANE 310 CRYSTALS 398 CURRENT 220 CYCLE 115 D 68 DANGER 203 DAYS 289 DECREASE 362 DEGREES 125 DELTA 10 DEVICE 303 DIRECTION 260 DISPLAY 261 DIVIDED 317 DOOR 314 DOWN 99 DUST 323 E 69 EAST 204 ECHO 114 ELECTRICIAN 262 EMERGENCY 111 ENGINE 385 ENTER 102 EQUAL 27 ERROR 169 ESTIMATED 345 EVACUATE 378 EXIT 58 EXPECT 382 F 70 FAILURE 226 FARENHEIT 221 FAST 28 FEET 238 FIELD 358 FINAL 367 FIRE 167 FLIGHT 417 FLOW 263 FOG 331 FOXTROT 264 FREEDOM 416 FREEZING 350 FREQUENCY 93 FROM 103 FUEL 374 FULL 399 G 71 GALLONS 265 GATE 266 GEAR 424 GET 104 GLIDE 357 GO 29 GOLF 268 GRAIN 381 GREEN 290 GREENWICH 342 GROUND 229 GUAGE 267 H 72 HAIL 324 HALF 315 HAVE 364 HAZE 353 HEADING 406 HEAVY 332 HENRY 269 HERTZ 241 HIGH 94 HOLD 105 HOTEL 227 HOURS 205 I 73 ICE 335 ICING 242 IDENTIFY 379 IDLE 393 IGNITE 387 IMMEADIATELY 366 IN 170 INBOUND 386 INCH 270 INCREASE 394 INDIA 292 INDICATED 340 INFORMATION 233 ING 200 INNER 422 INSTRUMENT 423 INTRUDER 271 IS 8 J 74 JULIET 272 K 75 KEY 173 KILO 206 KNOTS 359 L 76 LAND 333 LAUNCH 407 LEAN 403 LEFT 214 LEG 401 LEVEL 375 LIGHT 307 LIMA 273 LINE 18 LIST 426 LONG 376 LOW 30 M 77 MACHINE 5 MAINTAIN 402 MANUAL 291 MARKER 244 MAYDAY 243 MEAN 343 MEASURE 239 MEGA 38 METER 4 MICRO 297 MIDDLE 421 MIKE 274 MILE 240 MILLI 207 MINUS 15 MINUTES 275 MIST 344 MODERATE 341 MOTOR 276 MOVE 257 MOVING 199 MUCH 372 N 78 NEAR 228 NEW 400 NINER 415 NO 365 NORTH 210 NOT 16 NOVEMBER 208 NUMBER 234 O 79 OCLOCK 320 OF 106 OFF 2 OHMS 209 OIL 371 ON 3 OPEN 31 OPERATOR 36 OSCAR 95 OTHER 370 OUT 126 OUTER 420 OVER 171 P 80 PAPA 277 PARTIALLY 339 PASS 278 PASSED 311 PATH 361 PER 322 PERCENT 172 PLAN 383 PLEASE 174 PLUS 59 POINT 100 POSITION 279 POWER 39 PRESS 107 PRESSURE 211 PROBE 280 PULL 281 PUSH 282 Q 81 QUEBEC 283 R 82 RADAR 369 RAIN 330 RAISE 391 RANGE 108 READY 113 RED 222 REMARK 419 REPAIR 212 REPEATER 1 REPEET 237 RIGHT 213 ROMEO 294 S 83 SAFE 312 SAND 329 SCATTERED 354 SECONDS 301 SERVICE 235 SET 33 SEVERE 165 SHORT 404 SHOWERS 326 SHUT 60 SIERRA 42 SLEET 327 SLOPE 414 SLOW 304 SMOKE 22 SNOW 328 SOUTH 215 SPEED 34 SQUAWK 236 STALL 408 START 17 STOP 216 STORM 223 SWITCH 98 T 84 TANGO 285 TELEPHONE 230 TEMPERATURE 163 TEST 121 THE 9 THEE 224 THIN 334 THIS 7 THUNDER-STORM 164 TIME 20 TIMER 62 TOOL 305 TORNADO 166 TOUCHDOWN 409 TOWER 231 TRIM 413 TURBULENCE 349 TURN 109 U 85 UNDER 286 UNIFORM 287 UNIT 302 UNLIMITED 355 UP 122 V 86 VALVE 308 VARIABLE 336 VICTOR 295 VISABILITY 225 VOLTS 293 W 87 WAIT 21 WAKE 405 WATTS 12 WEATHER 162 WEST 219 WHISKEY 217 WHITE 319 WIND 325 X 88 X-RAY 218 Y 89 YANKEE 288 YELLOW 313 Z 90 ZULU 296 Male Numbers: 0 #0 1 #1 2 #2 3 #3 4 #4 5 #5 6 #6 7 #7 8 #8 9 #9 10 #10 11 #11 12 #12 13 #13 14 #14 15 #15 16 #16 17 #17 18 #18 19 #19 20 #20 30 #30 40 #40 50 #50 60 #60 70 #70 80 #80 90 #90 100 #100 1000 #1000 FEMALE VOICE FAFTER-NOON 160 FA_M 141 FEVENING 161 FGOOD 158 FIS 140 FMORN 159 FOCLOCK 143 FP_M 142 FTHE 138 FTIME 139 F0 128 F1 129 F2 130 F3 131 F4 132 F5 133 F6 134 F7 135 F8 136 F9 137 F10 144 F11 145 F12 146 F13 147 F14 148 F15 149 F16 150 F17 151 F18 152 F19 153 F20 154 F30 155 F40 156 F50 157
Speech Phrase Commands serial DTMF Description syntax: [CT] 183 Courtesy tone [CT] (ct#) [CW] 180 CW mode [CW] (tone) (wpm) [DAY] 177 Speak month/date [DAY] [ID] 11 Speak "Call" [ID] [LEV] 186 Speech level [LEV] (%) [OUT] 185 Set/clear output [OUT] (out#) (on/off) [PAG] 184 Send Moto page [PAG] (reed1) (reed2) [POZ] 186 Pause for input [POZ] [SPI] 182 Play DVR track [SPI] (addr) (track) Supress ID [SPI] S [SP] 181 Speach revert [SP] (use after [CW]) [S] 175 Salutation [S] [TC] 178 Temp. in C [TC] (input#) [TF] 179 Temp. in F [TF] (input#) [T] 176 Read time of day [T] XTRA 254 XTRA Allow long message (overwrites next message)